Pittsburgh’s Knob and Tube Epidemic

07 Monday Oct 2013

Posted by pittsburghcitywide in Uncategorized

≈ 1 Comment

Tags

electrical defects, electrical wiring, knob and tube, knob and tube wiring, old wiring

Pittsburgh has a lot of knobs and tubes.  And what is knob and tube?  It’s a type of electrical wiring, the original wiring in houses built in the early part of the century.  The name comes from the ceramic knobs that the wiring was secured to and the ceramic tubes that insulated the wires when they went through a joist or framing member.    DSCN2629

Here are some of the knobs.  In this case, the insulation is degraded.  The energized (hot) and neutral wires are on separate knobs run usually in separate bays of the framing, so there is no way for arcing to occur between the wires–If not improperly modified.

DSCN0848

DSCN9769

Sometimes the knob and tube is only visible in the attic or knee wall, having been replaced in the basement.  Insulation should not cover knob and tube wiring since it was not designed for it.

DSCN0317

 

 

 

 

 

 

The tubes are visible in this photo in the lower left.

 

 

 

 

In the basement you may see something like this, where newer wiring is spliced at a junction box to the knob and tube that goes upstairs somewhere.

DSCN9456

Improper splices to the knob and tube–the splices should be in a junction box.

Here are knob and tube conductors in the basement that have been spliced without the protection of a junction box–Not good.

DSCN7105

Knob and tube wiring buried in insulation.

DSCN7108

Buried in insulation.

Can you see the wire going into the insulation? With knob and tube, the energized and the neutral wires run on separate bays of the framing, so they can never touch.

Frequently the old knob and tube wiring was removed everywhere except for the lighting, because it was more complicated to open up the floors or ceilings to rewire.

DSCN6692

This is an access panel on the second floor. Sometimes there is a regular hinged cabinet door and the space is lined with asbestos.

DSCN8592

Knob and tube visible at light fixture.

Call to schedule: 412-862-1443 EMAIL: jthefleenor@gmail.com

Pages

  • BLOG
  • WELCOME HOME
  • WHAT WE DO
  • WHO WE ARE
  • SAMPLE REPORT
  • SCHEDULE AN INSPECTION
  • RADON TESTING
  • FYI

Blog at WordPress.com.

  • Follow Following
    • CITYWIDE HOME INSPECTIONS LLC
    • Already have a WordPress.com account? Log in now.
    • CITYWIDE HOME INSPECTIONS LLC
    • Customize
    • Follow Following
    • Sign up
    • Log in
    • Report this content
    • View site in Reader
    • Manage subscriptions
    • Collapse this bar
 

Loading Comments...